Accelerated Corrosion Monitoring
The accelerated reinforced bar corrosion test specimens were partially
immersed in a 5% sodium chloride solution in tanks located in the controlled
laboratory environment at 23℃ to 25℃ Corrosion was monitored by obtaining
half-cell potentials on a Hewlett Packard 3054 DL data acquisition
system,in conjunction with a saturated calomel electrode.The threshold
potential for corrosion initiation is taken at -270 millivolts [saturated calomel
electrode (SCE)],since the specimens are neither carbonated nor fully
saturated.Half-cell potentials numerically greater than this value indicate
that reinforcing steel corrosion is occurring.Each value plotted is an average
of three readings obtained on three specimens.